Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Rev. bras. ortop ; 57(4): 656-660, Jul.-Aug. 2022. tab, graf
Article in English | LILACS | ID: biblio-1394870

ABSTRACT

Abstract Objective To demonstrate the greater accuracy of panoramic radiographs of the lower limbs (long) in relation to short radiographs of the knee in the measurement of the mechanical axis of the lower limb after total knee arthroplasty (TKA). Methods A retrospective study was conducted to evaluate the accuracy of long and short postoperative radiographic images of 70 patients submitted to TKA in our service. The images were analyzed at random, at different times, by three orthopedists. In all images, the mechanical axis of the limb, femur and tibia were traced and femorotibial angles (FTAs) were calculated. The intraclass correlation coefficient (ICC) was calculated to evaluate the agreement of the measurement of the inter- and intra-observer mechanical axis. Results It was observed that there was high intra and interobserver agreement when panoramic radiographs were used, with minimum intra and interobserver ICC of 0.89, equivalent to a very strong agreement. On short radiographs in the anteroposterior incidence (AP) of the knee, the ICC showed moderate agreement, obtaining a maximum value of 0.75. Conclusion There is a significant difference in accuracy for the measurement of the mechanical axis of the lower limb, comparing long and short radiographs of the lower limb. Thus, for the proper measurement of the mechanical axis of the lower limb, we suggest the performance of long radiography in the postoperative period of TKA.


Resumo Objetivo Demonstrar a maior acurácia das radiografias panorâmicas de membros inferiores (longas) em relação às radiografias curtas do joelho na medida do eixo mecânico do membro inferior após a artroplastia total de joelho (ATJ). Métodos Foi realizado um estudo retrospectivo para avaliar a acurácia de imagens radiográficas longas e curtas pós-operatórias de 70 pacientes submetidos à ATJ em nosso serviço. As imagens foram analisadas ao acaso, em momentos distintos, por três ortopedistas. Em todas as imagens, o eixo mecânico do membro, do fêmur e da tíbia foram traçado,s e os ângulos femorotibiais (AFTs) foram calculados. O coeficiente de correlação intraclasse (CCI) foi calculado para avaliar a concordância da medida do eixo mecânico inter e intraobservador. Resultados Observou-se que houve alta concordância intra e interobservador quando utilizamos radiografias panorâmicas, apresentando CCI mínimo intrae interobservador de 0,89, equivalente a uma concordância fortíssima. Já nas radiografias curtas na incidência anteroposterior (AP) do joelho, o CCI mostrou-se com concordância moderada, obtendo valor máximo de 0,75. Conclusão Existe uma diferença significativa na acurácia para a medida do eixo mecânico do membro inferior, comparando-se radiografias longas e curtas do membro inferior. Assim, para a adequada mensuração do eixo mecânico do membro inferior, sugerimos a realização de radiografia longa no pós-operatório de ATJ.


Subject(s)
Humans , Postoperative Period , Retrospective Studies , Arthroplasty, Replacement, Knee , Knee/pathology , Knee/diagnostic imaging
3.
Rev. bras. ortop ; 52(2): 159-163, Mar.-Apr. 2017. tab, graf
Article in English | LILACS | ID: biblio-844103

ABSTRACT

ABSTRACT OBJECTIVE: Several studies show that patients undergoing total knee arthroplasty (TKA) tend to maintain or gain weight after the procedure, which would result in increased wear of the prosthesis and new surgical interventions in a smaller period of time in comparison with patients with adequate body mass index (BMI). The aim of this study was to investigate the effect of TKA surgery on these patients' BMI. METHODS: Initially the records were analyzed, chosen at random from 91 patients undergoing TKA during the period from August 2011 to July 2013. Patients were stratified by BMI as normal weight (BMI between 20 and 25), overweight (BMI between 25 and 30), and obesity (BMI > 30). They were re-evaluated in a minimum period of 18 months. RESULTS: The mean age of the sample population was 68.1 years; 69.1 for men and 67.2 for women. The mean preoperative BMI was 27.24 kg/m2. Among the study participants, in the preoperative period, 17 patients had normal weight, 65 were overweight, and nine were obese. Postoperative analysis showed weight loss in 41 patients (46%), and weight gain in 50 patients (54%). The mean postoperative BMI was 27.16 kg/m2, in general, experiencing a slight decline in the mean BMI of 0.08 kg/m2. CONCLUSION: Patients who underwent TKA did not achieve significant reduction in BMI after surgery.


RESUMO OBJETIVO: Diversos estudos demonstram que pacientes submetidos à artroplastia total do joelho (ATJ) tendem a manter ou a ganhar peso corporal após o procedimento, o que acarretaria aumento no desgaste da prótese e novas intervenções cirúrgicas em um tempo inferior àqueles que se mantém em índice de massa corporal (IMC) adequado. O objetivo deste estudo foi investigar o efeito da cirurgia de ATJ no IMC desses pacientes. MÉTODOS: Inicialmente foram analisados os prontuários, escolhidos ao acaso, de 91 pacientes submetidos à ATJ de agosto de 2011 a julho de 2013. Os pacientes foram estratificados pelo IMC como peso normal (IMC entre 20-25), sobrepeso (IMC entre 25-30) e obesidade (IMC > 30) e reavaliados em 18 meses no mínimo. RESULTADOS: A média de idade da população amostral foi de 68,1 anos, 69,1 para homens e 67,2 para mulheres. O IMC médio pré-operatório foi de 27,24 kg/m2. Entre os participantes do estudo, no período pré-operatório, 17 pacientes apresentavam peso normal; 65, sobrepeso e nove, obesidade. A análise pós-operatória demonstrou diminuição no peso em 41 pacientes (46%) e ganho ponderal em 50 (54%). O IMC médio pós-operatório foi de 27,16 kg/m2, de forma geral, ocorreu uma ligeira queda do IMC médio em 0,08 kg/m2. CONCLUSÃO: Os pacientes submetidos à ATJ não obtiveram redução significativa do IMC após o procedimento cirúrgico.


Subject(s)
Humans , Male , Female , Middle Aged , Arthroplasty, Replacement, Knee , Body Mass Index
4.
Rev. bras. ortop ; 50(1): 114-116, Jan-Feb/2015. graf
Article in English | LILACS | ID: lil-744645

ABSTRACT

Dislocation of the polyethylene component in knee arthroplasty is a rare complication. The main triggering factor is failure of the locking mechanism, which may result from technical errors of insertion, trauma or even implant failure. Here, a case of dislocation of the polyethylene component from the tibial base, nine years after revision arthroplasty, is reported. It is believed that this is the first such case reported in the Brazilian literature...


A luxação do polietileno em artroplastia do joelho é uma complicação rara. O principal fator desencadeante é a falha no mecanismo de travamento, que pode ser decorrente de erros técnicos na inserção, do trauma ou ainda de falha do implante. Os autores relatam caso de luxação do polietileno a partir da base tibial, nove anos após artroplastia de revisão. Acredita-se que seja o primeiro caso relatado na literatura nacional...


Subject(s)
Humans , Female , Aged , Arthroplasty, Replacement, Knee , Polyethylene , Prosthesis Failure
SELECTION OF CITATIONS
SEARCH DETAIL